Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; PP2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38231823

RESUMO

OBJECTIVE: Common pain assessment approaches such as self-evaluation and observation scales are inappropriate for children as they require patients to have reasonable communication ability. Subjective, inconsistent, and discontinuous pain assessment in children may reduce therapeutic effectiveness and thus affect their later life. METHODS: To address the need for suitable assessment measures, this paper proposes a spatiotemporal deep learning framework for scalp electroencephalogram (EEG)-based automated pain assessment in children. The dataset comprises scalp EEG data recorded from 33 pediatric patients with an arterial puncture as a pain stimulus. Two electrode reduction plans in line with clinical findings are proposed. Combining three-dimensional hand-crafted features and preprocessed raw signals, the proposed transformer-based pain assessment network (STPA-Net) integrates both spatial and temporal information. RESULTS: STPA-Net achieves superior performance with a subject-independent accuracy of 87.83% for pain recognition, and outperforms other state-of-the-art approaches. The effectiveness of electrode combinations is explored to analyze pain-related cortical activities and correspondingly reduce cost. The two proposed electrode reduction plans both demonstrate competitive pain assessment performance qualitatively and quantitatively. CONCLUSION AND SIGNIFICANCE: This study is the first to develop a scalp EEG-based automated pain assessment for children adopting a method that is objective, standardized, and consistent. The findings provide a potential reference for future clinical research.

2.
Sensors (Basel) ; 21(16)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-34450733

RESUMO

Wearable electrocardiogram (ECG) monitoring devices have enabled everyday ECG collection in our daily lives. However, the condition of ECG signal acquisition using wearable devices varies and wearable ECG signals could be interfered with by severe noises, resulting in great challenges of computer-aided automated ECG analysis, especially for single-lead ECG signals without spare channels as references. There remains room for improvement of the beat-level single-lead ECG diagnosis regarding accuracy and efficiency. In this paper, we propose new morphological features of heartbeats for an extreme gradient boosting-based beat-level ECG analysis method to carry out the five-class heartbeat classification according to the Association for the Advancement of Medical Instrumentation standard. The MIT-BIH Arrhythmia Database (MITDB) and a self-collected wearable single-lead ECG dataset are used for performance evaluation in the static and wearable ECG monitoring conditions, respectively. The results show that our method outperforms other state-of-the-art models with an accuracy of 99.14% on the MITDB and maintains robustness with an accuracy of 98.68% in the wearable single-lead ECG analysis.


Assuntos
Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Algoritmos , Arritmias Cardíacas , Bases de Dados Factuais , Frequência Cardíaca , Humanos , Processamento de Sinais Assistido por Computador
3.
Sensors (Basel) ; 19(20)2019 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-31615163

RESUMO

Body surface potential mapping (BSPM) is a valuable tool for research regarding electrocardiograms (ECG). However, the BSPM system is limited by its large number of electrodes and wires, long installation time, and high computational complexity. In this paper, we designed a wearable four-electrode electrocardiogram-sensor (WFEES) module that measures six-channel ECGs simultaneously for ECG investigation. To reduce the testing lead number and the measurement complexity, we further proposed a method, the layered (A, N) square-based (LANS) method, to optimize the ECG acquisition and analysis process using WFEES modules for different applications. Moreover, we presented a case study of electrode location optimization for wearable single-lead ECG monitoring devices using WFEES modules with the LANS method. In this study, 102 sets of single-lead ECG data from 19 healthy subjects were analyzed. The signal-to-noise ratio of ECG, as well as the mean and coefficient of variation of QRS amplitude, was derived among different channels to determine the optimal electrode locations. The results showed that a single-lead electrode pair should be placed on the left chest above the electrode location of standard precordial leads V1 to V4. Additionally, the best orientation was the principal diagonal as the direction of the heart's electrical axis.


Assuntos
Algoritmos , Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Adulto , Mapeamento Potencial de Superfície Corporal , Eletrodos , Feminino , Humanos , Masculino , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
4.
PLoS One ; 14(7): e0219910, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31344042

RESUMO

In this paper, we propose a human action recognition method using HOIRM (histogram of oriented interest region motion) feature fusion and a BOW (bag of words) model based on AP (affinity propagation) clustering. First, a HOIRM feature extraction method based on spatiotemporal interest points ROI is proposed. HOIRM can be regarded as a middle-level feature between local and global features. Then, HOIRM is fused with 3D HOG and 3D HOF local features using a cumulative histogram. The method further improves the robustness of local features to camera view angle and distance variations in complex scenes, which in turn improves the correct rate of action recognition. Finally, a BOW model based on AP clustering is proposed and applied to action classification. It obtains the appropriate visual dictionary capacity and achieves better clustering effect for the joint description of a variety of features. The experimental results demonstrate that by using the fused features with the proposed BOW model, the average recognition rate is 95.75% in the KTH database, and 88.25% in the UCF database, which are both higher than those by using only 3D HOG+3D HOF or HOIRM features. Moreover, the average recognition rate achieved by the proposed method in the two databases is higher than that obtained by other methods.


Assuntos
Atividades Humanas , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Análise por Conglomerados , Humanos , Gravação em Vídeo
5.
PLoS One ; 13(10): e0206170, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30339673

RESUMO

This paper presents a lightweight synthesis algorithm, named adaptive region segmentation based piecewise linear (ARSPL) algorithm, for reconstructing standard 12-lead electrocardiogram (ECG) signals from a 3-lead subset (I, II and V2). Such a lightweight algorithm is particularly suitable for healthcare mobile devices with limited resources for computing, communication and data storage. After detection of R-peaks, the ECGs are segmented by cardiac cycles. Each cycle is further divided into four regions according to different cardiac electrical activity stages. A personalized linear regression algorithm is then applied to these regions respectively for improved ECG synthesis. The proposed ARSPL method has been tested on 39 subjects randomly selected from the PTB diagnostic ECG database and achieved accurate synthesis of remaining leads with an average correlation coefficient of 0.947, an average root-mean-square error of 55.4µV, and an average runtime performance of 114ms. Overall, these results are significantly better than those of the common linear regression method, the back propagation (BP) neural network and the BP optimized using the genetic algorithm. We have also used the reconstructed ECG signals to evaluate the denivelation of ST segment, which is a potential symptom of intrinsic myocardial disease. After ARSPL, only 10.71% of the synthesized ECG cycles are with a ST-level synthesis error larger than 0.1mV, which is also better than those of the three above-mentioned methods.


Assuntos
Eletrocardiografia/instrumentação , Cardiopatias/diagnóstico , Processamento de Sinais Assistido por Computador/instrumentação , Adulto , Idoso , Algoritmos , Bases de Dados Factuais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Dispositivos Eletrônicos Vestíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...